综合成人亚洲偷自拍色,一个人看的免费高清www视频,伊人色综合一区二区三区,在线播放五十路熟妇,伊人激情av一区二区三区

95-55-6 structure, C6H7NO
2-aminophenol
CAS No.: 95-55-6 Formula: C6H7NO Molecular Weight: 109.12600
Search Suppliers

2-aminophenol

CAS No.:

95-55-6

Formula:

C6H7NO

Molecular Weight: 109.12600
Suppliers: All (81) China Suppliers (81) Price Available (15) Contractor (10)

Description

2-Aminophenol is an organic compound with the formula | C=6 | H=4 (OH)N| H=2 . Along with its isomer 4-aminophenol, it is an amphoteric molecule and a reducing agent. It is a useful reagent for the synthesis of dyes and heterocyclic compounds. Reflecting its slight hydrophilic character, white powder is moderately soluble in alcohols and can be recrystallised from hot water.

Numbering system

MDL number MFCD00007690
EINECS number 202-431-1

Properties

Appearance & Physical State

Colorless to light yellow liqui

Density

1.328

Boiling Point

164oC (11 mmHg)

Melting Point

172-177oC

Flash Point

168oC

Refractive Index

1.46 (20oC)

Water Solubility

17 g/L (20 oC)

Stability

Stable, but may be air or light sensitive. Incompatible with strong oxidizing agents.

Storage Condition

Keep away from heat, sparks, and flame. Keep away from sources of ignition. Store in a tightly closed container. Store in a cool, dry, well-ventilated area away from incompatible substances.

Safety Info

RTECS

SJ4950000

Hazard Class

6.1

Safety Statements

S28-S36/37

HS Code

29222900

WGK Germany

2

Packing Group

III

RIDADR

UN 2512

Risk Statements

R20/22; R68

Hazard Codes

Xn

SDS 1.0

Expand

SDS 1.0

Collapse
Download/Modify | Technical supported by XiXisys.com. For US version, EU version (23 languages) and more, please refer to xixisys.com/en/sds/search

SAFETY DATA SHEETS

According to Globally Harmonized System of Classification and Labelling of Chemicals (GHS) - Sixth revised edition

Version: 1.0

Creation Date: Aug 17, 2017

Revision Date: Aug 17, 2017

1.Identification

1.1 GHS Product identifier

Product name 2-aminophenol

1.2 Other means of identification

Product number -
Other names Ortho Amino Phenol

1.3 Recommended use of the chemical and restrictions on use

Identified uses For industry use only.
Uses advised against no data available

1.4 Supplier's details

Company MOLBASE (Shanghai) Biotechnology Co., Ltd.
Address Floor 4 & 5, Building 12, No. 1001 North Qinzhou Road,
Xuhui District, Shanghai, China
Telephone +86(21)64956998
Fax +86(21)54365166

1.5 Emergency phone number

Emergency phone number +86-400-6021-666
Service hours Monday to Friday, 9am-5pm (Standard time zone: UTC/GMT +8 hours).

2.Hazard identification

2.1 Classification of the substance or mixture

Acute toxicity - Oral, Category 4

Acute toxicity - Inhalation, Category 4

Germ cell mutagenicity, Category 2

2.2 GHS label elements, including precautionary statements

Pictogram(s)
Signal word

Warning

Hazard statement(s)

H302 Harmful if swallowed

H332 Harmful if inhaled

H341 Suspected of causing genetic defects

Precautionary statement(s)
Prevention

P264 Wash ... thoroughly after handling.

P270 Do not eat, drink or smoke when using this product.

P261 Avoid breathing dust/fume/gas/mist/vapours/spray.

P271 Use only outdoors or in a well-ventilated area.

P201 Obtain special instructions before use.

P202 Do not handle until all safety precautions have been read and understood.

P280 Wear protective gloves/protective clothing/eye protection/face protection.

Response

P301+P312 IF SWALLOWED: Call a POISON CENTER/doctor/…if you feel unwell.

P330 Rinse mouth.

P304+P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.

P312 Call a POISON CENTER/doctor/…if you feel unwell.

P308+P313 IF exposed or concerned: Get medical advice/ attention.

Storage

P405 Store locked up.

Disposal

P501 Dispose of contents/container to ...

2.3 Other hazards which do not result in classification

none

3.Composition/information on ingredients

3.1 Substances

Chemical name Common names and synonyms CAS number EC number Concentration
2-aminophenol 2-aminophenol 95-55-6 none 100%

4.First-aid measures

4.1 Description of necessary first-aid measures

General advice

Consult a physician. Show this safety data sheet to the doctor in attendance.

If inhaled

Fresh air, rest. Refer for medical attention.

In case of skin contact

Rinse and then wash skin with water and soap.

In case of eye contact

First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then refer for medical attention.

If swallowed

Rinse mouth. Give a slurry of activated charcoal in water to drink. Refer for medical attention .

4.2 Most important symptoms/effects, acute and delayed

SYMPTOMS: Symptoms of exposure to this compound include redness of the skin, coughing, and nausea. ACUTE/CHRONIC HAZARDS: Very toxic. May cause irritation on contact. Hazardous decomposition.

4.3 Indication of immediate medical attention and special treatment needed, if necessary

Immediate first aid: Ensure that adequate decontamination has been carried out. If patient is not breathing, start artificial respiration, preferably with a demand-valve resuscitator, bag-valve-mask device, or pocket mask, as trained. Perform CPR as necessary. Immediately flush contaminated eyes with gently flowing water. Do not induce vomiting. If vomiting occurs, lean patient forward or place on left side (head-down position, if possible) to maintain an open airway and prevent aspiration. Keep patient quiet and maintain normal body temperature. Obtain medical attention. /Aniline and related compounds/

5.Fire-fighting measures

5.1 Extinguishing media

Suitable extinguishing media

Use dry chemical, carbon dioxide, or alcohol foam extinguishers. Vapors are heavier than air and will collect in low areas. Vapors may travel long distances to ignition sources and flashback. Vapors in confined areas may explode when exposed to fire. Storage containers and parts of containers may rocket great distances, in many directions. If material or contaminated runoff enters waterways, notify downstream users of potentially contaminated waters. Notify local health and fire officials and pollution control agencies. From a secure, explosion-proof location, use water spray to cool exposed containers. If cooling streams are ineffective (venting sound increases in volume and pitch, tank discolors or shows any signs of deforming), withdraw immediately to a secure position ... The only respirators recommended for fire fighting are self-contained breathing apparatuses that have full facepieces and are operated in a pressure-demand or other positive-pressure mode. /Anisidines/

5.2 Specific hazards arising from the chemical

Excerpt from ERG Guide 152 [Substances - Toxic (Combustible)]: Combustible material: may burn but does not ignite readily. Containers may explode when heated. Runoff may pollute waterways. Substance may be transported in a molten form. (ERG, 2016)

5.3 Special protective actions for fire-fighters

Wear self-contained breathing apparatus for firefighting if necessary.

6.Accidental release measures

6.1 Personal precautions, protective equipment and emergency procedures

Use personal protective equipment. Avoid dust formation. Avoid breathing vapours, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust. For personal protection see section 8.

6.2 Environmental precautions

Personal protection: chemical protection suit and particulate filter respirator adapted to the airborne concentration of the substance. Do NOT let this chemical enter the environment. Sweep spilled substance into covered sealable containers. If appropriate, moisten first to prevent dusting. Carefully collect remainder. Then store and dispose of according to local regulations.

6.3 Methods and materials for containment and cleaning up

Spill handling: keep dust under control. Use a vacuum or wet method to reduce dust during clean-up. Do not sweep. Evacuate persons not wearing protective equipment from area of spill or leak until clean-up is complete. Remove all ignition sources. Collect powdered material in the most convenient and safe manner and deposit in sealed containers. Ventilate area after clean-up is complete. It may be necessary to contain and dispose of this chemical as a hazardous waste. If material or contaminated runoff enters waterways, notify downstream users of potentially contaminated waters. Contact your Department of Environmental Protection of your regional office of the federal EPA for specific recommendations. /Aminophenols/

7.Handling and storage

7.1 Precautions for safe handling

Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Avoid exposure - obtain special instructions before use.Provide appropriate exhaust ventilation at places where dust is formed. For precautions see section 2.2.

7.2 Conditions for safe storage, including any incompatibilities

Store in an area without drain or sewer access. Well closed. Separated from oxidants and food and feedstuffs.Store in tightly closed containers in a cool, well-ventilated area. Aminophenols must be stored to avoid contact with strong oxidizers (such as chlorine, bromine, and fluorine), since violent reactions occur. /Aminophenols/

8.Exposure controls/personal protection

8.1 Control parameters

Occupational Exposure limit values

no data available

Biological limit values

no data available

8.2 Appropriate engineering controls

Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.

8.3 Individual protection measures, such as personal protective equipment (PPE)

Eye/face protection

Safety glasses with side-shields conforming to EN166. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).

Skin protection

Wear impervious clothing. The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace. Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique(without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.

Respiratory protection

Wear dust mask when handling large quantities.

Thermal hazards

no data available

9.Physical and chemical properties

Physical state Colorless to light yellow liqui
Colour Crystals, rapidly becoming brown
Odour no data available
Melting point/ freezing point 172-177oC
Boiling point or initial boiling point and boiling range 164oC (11 mmHg)
Flammability Combustible. Gives off irritating or toxic fumes (or gases) in a fire.
Lower and upper explosion limit / flammability limit no data available
Flash point 168oC
Auto-ignition temperature 190°C
Decomposition temperature 170-174°C
pH no data available
Kinematic viscosity no data available
Solubility In water:17 g/L (20 oC)
Partition coefficient n-octanol/water (log value) no data available
Vapour pressure 5X10-4 Hg at 25°C (est)
Density and/or relative density 1.328
Relative vapour density (air = 1): 3.77
Particle characteristics no data available

10.Stability and reactivity

10.1 Reactivity

no data available

10.2 Chemical stability

Crystals readily becoming gray on exposure to light /Hydrochloride/

10.3 Possibility of hazardous reactions

CombustibleO-AMINOPHENOL can react with oxidizing agents. THF forms explosive products with 2-aminophenol [Lewis 3227].

10.4 Conditions to avoid

no data available

10.5 Incompatible materials

Incompatible with acids, acid chlorides, and anhydrides, chloroformates, strong oxidizing agents.

10.6 Hazardous decomposition products

When heated to decomposition it emits toxic /nitroxides/.

11.Toxicological information

Acute toxicity

  • Oral: LD50 Rat oral 1300 mg/kg
  • Inhalation: no data available
  • Dermal: no data available

Skin corrosion/irritation

no data available

Serious eye damage/irritation

no data available

Respiratory or skin sensitization

no data available

Germ cell mutagenicity

no data available

Carcinogenicity

no data available

Reproductive toxicity

no data available

STOT-single exposure

no data available

STOT-repeated exposure

no data available

Aspiration hazard

no data available

12.Ecological information

12.1 Toxicity

  • Toxicity to fish: no data available
  • Toxicity to daphnia and other aquatic invertebrates: no data available
  • Toxicity to algae: no data available
  • Toxicity to microorganisms: no data available

12.2 Persistence and degradability

AEROBIC: In a screening study using a soil inoculum and 2-aminophenol at 15 ppm, >64 days were required for total loss of UV absorbancy due to cleavage of the benzene ring(1). 2-Aminophenol, present at 100 mg/L, in an electrolytic respirometry screening test using an activated sludge inoculum, reached 45% of the theoretical BOD in 10 days(2). A rate constant of 0.279X10-2 per hour was measured for 2-aminophenol in a screening test using a non-adapted activated sludge inoculum(3). 2-Aminophenol, at 200 mg/L chemical oxygen demand reached 95% removal in 5 days in a screening test using acclimated activated sludge at 100 mg/L(4). Screening tests using activated sludge adapted to either phenol or a mixture of cresols reported rate constants of 1.86X10-3(5) and 6.73X10-3(6), respectively, for the biodegradation of 2-aminophenol.

12.3 Bioaccumulative potential

An estimated BCF of 3 was calculated in fish for 2-aminophenol(SRC), using a log Kow of 0.62(1) and a regression-derived equation(2). According to a classification scheme(3), this BCF suggests the potential for bioconcentration in aquatic organisms is low(SRC).

12.4 Mobility in soil

Using a structure estimation method based on molecular connectivity indices(1), the Koc of 2-aminophenol can be estimated to be 90(SRC). According to a classification scheme(2), this estimated Koc value suggests that 2-aminophenol is expected to have high mobility in soil. However, anilines are expected to bind strongly to humus or organic matter in soils due to the high reactivity of the aromatic amino group(3-4), suggesting that mobility may be much lower in some soils(SRC). Measured pKa values are 4.72 and 9.71(5), for the amine and hydroxy functional groups, respectively(6); 2-aminophenol is amphoteric and behaves either as a weak acid or weak base; the basic character usually predominates(5). At pH 8.4, 25.5% of added 2-aminophenol is sorbed by an organoclay(7). The sorptive capacity of clays for amine-substituted phenolic sorbate decreased with increasing pH above the corresponding pKa(8).

12.5 Other adverse effects

no data available

13.Disposal considerations

13.1 Disposal methods

Product

The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.

Contaminated packaging

Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.

14.Transport information

14.1 UN Number

ADR/RID: UN2512 IMDG: UN2512 IATA: UN2512

14.2 UN Proper Shipping Name

ADR/RID: AMINOPHENOLS (o-, m-, p-)
IMDG: AMINOPHENOLS (o-, m-, p-)
IATA: AMINOPHENOLS (o-, m-, p-)

14.3 Transport hazard class(es)

ADR/RID: 6.1 IMDG: 6.1 IATA: 6.1

14.4 Packing group, if applicable

ADR/RID: III IMDG: III IATA: III

14.5 Environmental hazards

ADR/RID: no IMDG: no IATA: no

14.6 Special precautions for user

no data available

14.7 Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code

no data available

15.Regulatory information

15.1 Safety, health and environmental regulations specific for the product in question

Chemical name Common names and synonyms CAS number EC number
2-aminophenol 2-aminophenol 95-55-6 none
European Inventory of Existing Commercial Chemical Substances (EINECS) Listed.
EC Inventory Listed.
United States Toxic Substances Control Act (TSCA) Inventory Listed.
China Catalog of Hazardous chemicals 2015 Listed.
New Zealand Inventory of Chemicals (NZIoC) Listed.
Philippines Inventory of Chemicals and Chemical Substances (PICCS) Listed.
Vietnam National Chemical Inventory Not Listed.
Chinese Chemical Inventory of Existing Chemical Substances (China IECSC) Listed.

16.Other information

Information on revision

Creation Date Aug 17, 2017
Revision Date Aug 17, 2017

Abbreviations and acronyms

  • CAS: Chemical Abstracts Service
  • ADR: European Agreement concerning the International Carriage of Dangerous Goods by Road
  • RID: Regulation concerning the International Carriage of Dangerous Goods by Rail
  • IMDG: International Maritime Dangerous Goods
  • IATA: International Air Transportation Association
  • TWA: Time Weighted Average
  • STEL: Short term exposure limit
  • LC50: Lethal Concentration 50%
  • LD50: Lethal Dose 50%
  • EC50: Effective Concentration 50%

References

  • IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
  • HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
  • IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
  • eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
  • CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
  • ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
  • ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
  • Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
  • ECHA - European Chemicals Agency, website: https://echa.europa.eu/

Disclaimer: The above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The information in this document is based on the present state of our knowledge and is applicable to the product with regard to appropriate safety precautions. It does not represent any guarantee of the properties of the product. We as supplier shall not be held liable for any damage resulting from handling or from contact with the above product.

MSDS

Expand
1H NMR : PredictExpand

NMR Spectrum 1H NMR : Predict

Collapse
95-55-6 NMR spectrum
More

GC Analysis

Total 3 Documents >>
Column type Active phase Temperature (°C) Retention Index (I) Temperature Control Method
Packed SE-30 180. 1251. isothermal
Packed SE-30 - 1242. custom temperature program
Capillary SE-30 - 1242. custom temperature program
Recommended Suppliers
More Suppliers>>
Other items you might be interested in
Category in MOLBASE